Talk to us?
Anesthesia Machine ZAM-A16 with a flowmeter range of 0.1 to 10 L/min for each gas, offers flexibility across various clinical scenarios. It allows for customizable inspiratory-to-expiratory ratios from 4:1 to 1:8. The vaporizer integrates temperature, pressure, and flow compensation, along with a self-lock mechanism. Its separate electric and gas circuits enhance durability. Our machine offers multiple customizable triggers, including pressure and flow, for optimal ventilation support.
Category: Anesthesia Machines
$7300
Ventilation Mode | IPPV, A/C, PCV, SIMV, SIGH, MAUN |
Gas Source | O₂, N₂O/O₂, AIR |
Flowmeter Range | O₂: 0.1 to 10 L/min N₂O: 0.1 to 10 L/min AIR: 0.1 to 10 L/min |
Rapid Oxygen Supply | 25 L/min to 75 L/min |
Oxygen Concentration | 15% to 100% |
Inspiratory-To- Expiratory Ratio (I:E) | 4:1 to 1:8 |
Tidal Volume (VT) | 0,20ml to 1500ml |
Minute Volume (MV) | 0 L/min to 100 L/min |
Respiratory Rate (Freq) | 1/min to 100/min |
Positive End-Expiratory Pressure (PEEP) | 0cmH₂O to 30cmH₂O |
Pressure Control (PC) | 5cmH₂O to 60cmH₂O |
Pressure Trigger (PTr) | -20 cmH₂O to 20 cmH₂O |
Flow Trigger (FTr) | OFF, 1 L/min to 30 L/min |
Inspiratory Time (Tinsp) | 0s to 12s |
Inspiratory Pause (TIP) | 0s to 6s |
Apnea Ventilation | OFF, 5s to 60s |
SIGH | 0 (off) 1/100 to 5/100 |
Gas Pressure | 280kPa to 600kPa |
Bellow Volume | 1.5 L |
Graphical Display | P-T (pressure – time) F-T (flow – time) P-V loop (pressure – volume loop) |
Alarms | AC Power Failure Alarm: Power failure or no connection Internal Battery Low Voltage: < 11.3 ±0.3V No Tidal Volume: ≤5mL within 6s High Oxygen Concentration: 19% to 100% Low Oxygen Concentration: 18% to 99% High Airway Pressure: 20cmH₂O to 100 cmH₂O Low Airway Pressure: 0 cmH₂O to 20 cmH₂O High Minute Volume: Adult (5L/min to 20L/min) Low Minute Volume: Pediatric (1L/min to 15L/min, 0 to 10L/min) Continuous Pressure: (PEEP + 1.5 kPa) over 16s Suffocation Warning: 5s to 60s no spontaneous ventilation Maximum Limited Pressure: ≤ 12.5 kPa |
Error Indicators | Fan Error: Shown on screen Oxygen Deficit: Shown on screen |
Display | 10.4"Colorful TFT LCD display screen |
Power Consumption | 85VA |
Power Supply | 100V to 240V, 50/60Hz |
Packaging Dimensions (L×W×H) | 740 × 795 × 1540 mm |
Net Weight | 52.5 kg |
Gross Weight | 119 kg |
For adult, pediatric, and neonatal patients
Multiple ventilation modes
Rapid oxygen supply
Adjustable tidal volume and respiratory rates
Real-time graphical displays
Vaporizer with compensation and safety lock
13 alarms with visual and sound alerts
Built-in battery with 2–3 hours backup
Multilingual interface with 8 languages
Accessories | Quantity |
Anesthetic breathing system | 1pc |
CO₂ sensor | 1pc |
Anesthetic vaporizer | 2pcs |
Power cord (4m) | 1pc |
Fuse (250V) | 11pcs |
O₂ cell | 1pc |
Adult anesthesia breathing circuit (reusable) | 2pc |
Child anesthesia breathing circuit (reusable) | 2pc |
Breathing tube | 1pc |
Y connector (Adult) | 1pc |
Y connector (Children) | 1pc |
L connector | 2pc |
Straight connector | 1pc |
Reservoir bag 1L | 1pc |
Reservoir bag 3L | 1pc |
Anesthetic mask adult | 1pc |
Anesthetic mask infant | 1pc |
High pressure O₂ hose | 1pc |
High pressure air hose | 1pc |
High pressure N₂O hose | 1pc |
Auxiliary Common Gas Outlet (ACGO) | 1pc |
Drawers | 2pc |
Vaporizer | 2pc |
Spare Cylinder yoke, 1 O₂, includes gauges
Spare Cylinder yoke, 1 N₂O, includes gauges
Anesthetic gas scavenging system
Disposable adult breathing circuit
Disposable pediatric breathing circuit
Patient monitor
Our Anesthesia Machine ZAM-A16 is used in intensive care units, operating rooms, and anesthesiology departments for adult, pediatric, and neonatal inhalation anesthesia and respiratory management.
Jul 22, 2024