Zimed Biochemistry Analyzers deliver essential diagnostics for disease detection, treatment monitoring, and health evaluation. We offer both automatic and semi-automatic biochemistry analyzers to improve laboratory efficiency. These analyzers use specific wavelengths to measure absorbance and identify substances accurately. With intuitive interfaces and advanced data management, they provide effortless operation and consistent, dependable results. Our biochemistry analyzers are compact, space-efficient, and perfect for laboratories of any size.
Wavelength Precision : ±2 nm (width <10 nm)
Absorbance Precision : Outside 0.0001 Abs,
Inside 0.00001 Abs
Repeatability CV : < 1%
Performance : Test Speed: 120 tests/hour
Accuracy and Sensitivity : Absorbance Range: 0 to 4.000 Abs
Absorbance Precision: inside 0.00001 Abs
Repeatability CV: < 1%
Carry-over: < 0.1%
Test Modes : Kinetic, End-point, Fixed-time, Turbidimetry, Absorbance
Photometric Range : 0.0000 to 4.0000 Abs
Resolution : 0.0001 Abs
Flow Cell Capacity and Optical Path : 32μL, 10mm
Test Methods : 1-point end, 2-point end (Sample blank), Kinetics, Fixed-time, Coagulation
Photometric Range : 0.0000 to 4.0000 Abs
Resolution : 0.0001 Abs
Test Speed : 300 tests/hour (Mono reagent or double reagent)
Test Methods : Colorimetric, Turbidity
Test Principles : 1 point end, 2 point end, Fixed-Time, Kinetics
Aspiration volume : 200 µl to 2000 µl
Flow cell : 32 µl
Assay type : Kinetics, Bi-chromatic, End-point, Differential, Fixed time, Multi-standard
Assay type : End-point, Two point, Kinetic, Reagent blank sample blank, Immunity nephelometry and Multiplication selectable calibration methods
Wave length : 340 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm, 670 nm
Flow cell : 32 µl quartz / metal flow cell
Assay type : Kinetic, End point, Two point and Absorbance
Wave length : 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 630 nm
Flow cell : 32 µl quartz glass
Frequently Asked Question
Common tests include glucose, cholesterol, liver enzymes, kidney function markers, electrolytes, and proteins.
Throughput varies by model, typically ranging from 100 to over 2,000 tests per hour in high-end analyzers.
Regular maintenance includes daily, weekly, and monthly cleaning and calibration. Preventive maintenance should be scheduled every 3 to 6 months, as recommended by the manufacturer.
Yes, many analyzers have settings or models specifically designed for veterinary diagnostics.
Yes, but proper safety precautions must be followed, including handling reagents correctly, wearing PPE, and ensuring proper waste disposal.