ZAM-A14

Anesthesia Machine ZAM-A14

www.zimed.com | info@zimed.com

Overview

Anesthesia ZAM-A14 has a number of operating modes, including pressure restriction and volume control. The gadget has a high-precision flowmeter, an audio and video alarm system, and a 10.4-inch TFT LCD display screen. An inbuilt backup battery powers the device in an emergency. It includes a variety of ventilation options, including IPPV, A/C, PSV, PCV, SIMV, SIGH, and MANUAL, and it can also be adjusted to the patient's needs.

Specifications :
Ventilation Mode IPPV, A/C, PCV, PSV SIMV, SIGH, MANUAL
Ventilator Parameter Range
Flowmeter O2 (0.1 – 10 L/min); N2O (0.1 – 10 L/min); AIR (0.1 – 10 L/min)
Rapid Oxygen Supply 25 L/min – 75 L/min
Tidal Volume 0.20 mL – 1500 mL
Frequence 1/min – 100/min
Pressure triggering Sensitivity -20 cm H2O – 0 cm H2O (Based on PEEP)
PEEP 0 cm H2O – 30 cm H2O)
Flow Trigger Sensitivity 0.5 L/min – 30 L/min
SIGH 0 (off) 1/100 – 5/100
Apnea Ventilation OFF, 5sec – 60 sec
PC (Pressure Control) 5 cm H2O – 60 cm H2O
Limit 20 cm H2O – 100 cm H20
Monitoring Parameter
Frequence 0 /min – 100 /min
Tidal Volume 0 mL – 2000 mL
MV 0 L/min – 100 L/min
Oxygen Concentration 15% - 100%
Alarm & Protection
AC power failure Alarm Power failure or no connection
Low Voltage alarm for back up battery < 11.3 ± 0.3 V
No Tidal Volume ≤ 5 mL within 6s
Oxygen Concentration Alarm 19% - 100% (HIGH); 18% - 99% (LOW)
Airway Pressure Alarm 20 cmH2O – 100 cm H2O (HIGH); 0 cm H2O – 20 cm H2O (LOW)
Minute Volume Alarm Adult (5 L/min – 20 L/min); Child (1 L/min – 15 L/min) (HIGH); 0 – 10 L/min (LOW)
Continuous Pressure Alarm (PEEP + 1.5 kPa) over 16s
Suffocation Warning 5s – 60s no spontaneous ventilation
The Maximum Limited Pressure < 12.5 kPa
Fan Error Show On Screen
Oxygen Deficit Show On Screen
Working Condition
Gas Source O2, N2O, AIR
Pressure 280 kPa – 600 kPa
Voltage 100 – 240 V
Power Frequency 50 / 60 Hz
Packing Size
Dimensions (L × W × H) 930 × 750 × 1405 mm
Net Weight 124 Kg
Gross Weight 195 Kg
Features :
  • It is simple, safe, reliable, and easy-to-use
  • Flexible configuration
  • 4 static caster with self-locking function
  • TFT LCD screen display, 10.4-inch
  • Multiple working modes
  • Audio-video alarm system for power failure, voltage
  • Built-in backup battery
  • High precision flowmeter
  • Integrated breathing circuit
  • Vaporizer with temperature, pressure, flow compensation
Applications :

In the world of medicine and hospitals, anesthesia machines are utilized in intensive care units (ICU), operating rooms, and anesthesiology departments.