Patient Monitor ZPM-A104

Patient Monitor ZPM-A104

Patient monitor ZPM-A104 is used to keep an eye on patients' vital signs. It sports a 10-inch TFT LCD screen with an 800 × 600 resolution. The instrument has a calibration of 1 mV and a 5-wire ECG cable for input. Either the waveform or the data type is the output type that is visible on the monitor. The design is portable, light, and small. They are simple to use and upgrade because they support USB, SD cards, keyboards, and mouse.

Product Enquiry View Catalog
Specification
Display 10-inch TFT LCD
Resolution 800 × 600 pixels
Waveform Up to 7
ECG
Input 3/5 wires ECG cable
Lead Selection I, II, III, aVR, aVL, aVF, V
Gain Selection 0.25, 0.5, 1, 2
Sweep Speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Heart rate range 15 – 300 bpm
Calibration ± 1 mV
Accuracy ± 1 bpm or ± 1% (Select the bigger data)
NIBP (Oscillometric method)
Philosophy Adult, pediatric and neonate
Measurement Type Systolic, diastolic, mean
Parameter Automatic, continuous measurement
Method manual mmHG/kPA selection
Accuracy ± 3 mmHg or ± 2 %
SPO2
Display Type Waveform, Data
Measurement Range 0 – 100%
Accuracy ± 3% (between 70% - 100%)
Pulse rate range 20 – 300 bpm
Precision ± 1 bpm or ± 2% (Select the bigger data)
Resolution 1 bpm
2-Temperature (rectal and surface)
Number of channel 2 Channel
Measurement range 0 – 50 ℃
Accuracy ± 0.2 ℃
Resolution 0.1 ℃
Display T1, T2
Unit ℃ / ℉ selection
Refresh Cycle 1s – 2s
Respiration(impedance and nasal tube)
Measurement type 0 – 150 rpm
Accuracy ± 1 bpm or ± 5%, select the bigger data
Resolution 1 rpm
Packaging Size (L × D × H) 340 × 340 × 280 mm
Net Weight 6 Kg
Features
  • Simple, safe, reliable, and easy-to-use
  • Low consumption, no-fan design
  • Compact and portable
  • Keyboards, mouse, USB, and SD cards are all supported
  • Cutting-edge SPO2, NIBP, ECG measurement technology
  • 10-inch TFT LCD display, touch screen
  • Up to 7 waveforms
  • Display type, waveform, and data
  • Wireless networking system
  • Titration table, drug calculation
  • Alarm events and ARR review
  • Easy upgradation

Optional Accessories

Test Parameter Value
ETCO2 – plug and play Measurement Type Side Stream
Range 0 – 10.0 %, 0 -76 mmHg
Accuracy 5.0%,+-0.28kPa,+-2mmHg,5.0%,+-10%
2-IBP Measurement Range -10 - 300 mmHg
Number of channel 1 or 2 channel
Accuracy +-1 mmHg or +-2 %, Select the bigger data
Pressure tag ART, CVP, RVP, LAP, RAP, PAP, ICP, LVP
12 Leads ECG Input 3/5/10 wires ECG cables
Lead Section I, II, III, aVR, aVL, aVF, V (V1 – V6)
Sweep Speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Heart rate range 15 – 380 bpm
Calibration +- 1 mV

Applications

Patient monitors are suitable for adults, pediatrics, and neonates in the fields of medical institutes (ICU, NICU, PACU, etc.).

Related products