Zimed offer mobile and portable X-ray machines featuring high frequency inverter to emit good quality X-rays at minimal radiation doses. Give consistent and replicable radiation dose and features kV analog closed loop control, mAs digital closed loop control and micro processing real-time control radiography techniques.
Power output | 2.5 kW |
---|---|
X-ray tube (Fixed anode focus) | 1.5 mm |
mAs | 1.0 to 160 mAs (45 steps) |
Inverter frequency | 50 kHz |
Tube voltage | 40 to 100 kV |
Battery | |
Tube current |
40 to 49 kV, 50 mA 50 to 59 kV, 42 mA 60 to 69 kV, 36 mA 70 to 79 kV, 31 mA 80 to 89 kV, 28 mA 90 to 100 kV, 25 mA |
Operation mode | Wire and wireless control |
Power supply |
220 V ± 10 % 50 Hz (R = ≤ 1.0 Ω) |
Display mode | LCD |
Power output | 3.5 kW |
---|---|
X-ray tube (Fixed anode focus) | 1.5 mm |
mAs | 1.0 to 125 mAs (43 steps) |
Inverter frequency | 50 kHz |
Tube voltage | 40 to 110 kV |
Battery | |
Tube current |
40 to 49 kV, 63 mA 50 to 59 kV, 55 mA 60 to 69 kV, 45 mA 70 to 79 kV, 40 mA 80 to 89 kV, 36 mA 90 to 99 kV, 32 mA 100 to 110 kV, 20 mA |
Operation mode | Wire and wireless control |
Power supply |
220 V ± 10 % ; 50 Hz (R = ≤ 1.0 Ω) |
Display mode | LCD |
Power output | 5 kW |
---|---|
X-ray tube (Fixed anode focus) | 1.5 mm |
mAs | 1.0 to 180 mAs (46 steps) |
Inverter frequency | 50 kHz |
Tube voltage | 40 to 100 kV |
Battery | |
Tube current |
40 to 9 kV, 100 mA
50 to 59 kV, 77 mA 60 to 69 kV, 64 mA 70 to 79 kV, 55 mA 80 to 89 kV, 49 mA 90 to 99 kV, 44 mA 100 to 109 kV, 32 mA 110 to 120 kV, 25 mA |
Operation mode | Wire and wireless control |
Power supply |
220 V ± 10 % ; 50 Hz (R = ≤ 1.0 Ω) |
Display mode | LCD |
Power output | 5 kW |
---|---|
X-ray tube (Fixed anode focus) | 1.5 mm |
mAs | 1.0 to 180 mAs (46 steps) |
Inverter frequency | 50 kHz |
Tube voltage | 40 to 100 kV |
Battery | Internalized battery |
Tube current |
40 to 9 kV, 100 mA
50 to 59 kV, 77 mA 60 to 69 kV, 64 mA 70 to 79 kV, 55 mA 80 to 89 kV, 49 mA 90 to 99 kV, 44 mA 100 to 109 kV, 32 mA 110 to 120 kV, 25 mA |
Operation mode | Wire and wireless control |
Power supply |
220 V ± 10 % ; 50 Hz (R = ≤ 1.0 Ω) |
Display mode | LCD |
Output power | 4 kW |
---|---|
X-ray tube (Focus) | 0.6 / 1.6 mm |
mAs (Adjustable) | 1 to 190 mAs |
Tube voltage (Adjustable) | 40 to 110 kV |
Nominal power | 100 kV, 40 mA, 0.1 s, 4 kW |
mA (Adjustable) | 36 to 60 mA |
Power supply | 220 V ± 22V ; 50 to 60 Hz ± 1Hz |
Anode heat capacity (X-ray tube) |
76 kHU |
Machine frame size |
Highest : 1060 × 790 × 2210 mm Lowest : 1060 × 790 × 1240 mm |
Size | 290 × 260 × 230 mm |
Weight | 18.8 kg |
Generator kV range | 40 to 125 kV |
---|---|
Generator mAs range | 0.1 to 100 mAs |
Generator mA range | 10 to 100 mA |
Communication mode | RS232/Bluetooth |
Exposure mode | Wired/Wireless |
X-ray tube Focal spots | 0.6/1.8 mm |
X-ray tube Anode Angle | 15° |
Power | 5 kW |
Electric source | AC 210 to 230 V / AC 100 V to 120 V |
Size | 505 × 348 × 230 mm |
Weight | 16 kg |