0

Talk to us?

Pulse Oximeters

Our Pulse Oximeters are used to non-invasively measure oxygen saturation levels in the blood, providing critical insights into a patient’s respiratory function. Zimed offers two varieties: fingertip pulse oximeters and handheld pulse oximeters. Fingertip models are compact and user-friendly for personal or at-home use. They offer quick readings, featuring bright OLED displays for easy visibility. Handheld models are more versatile for both clinical and home settings. They provide advanced functionalities and data logging and connectivity options with other medical devices or health monitoring systems. These oximeters provide accurate readings, essential for managing respiratory or cardiovascular patients.

compare
Pulse Oximeters - Fingertip Pulse Oximeter ZFPO-A10

Fingertip Pulse Oximeter ZFPO-A10

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)
Perfusion Index (PI)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%; 0% to 69%

PR : Measurement range: 30 to 250 bpm
Resolution: 1 bpm
Accuracy: 30bpm to 99bpm ±2bpm; 100 bpm to 250bpm ±2%

compare
Pulse Oximeters - Fingertip Pulse Oximeter ZFPO-A11

Fingertip Pulse Oximeter ZFPO-A11

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)
Perfusion Index (PI)
Respiratory rate (RR)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%; 0% to 69%

PR : Measurement range: 30 to 250 bpm
Resolution: 1 bpm
Accuracy: 30bpm to 99bpm ±2bpm; 100bpm to 250bpm ±2%

compare
Pulse Oximeters - Fingertip Pulse Oximeter ZFPO-A12

Fingertip Pulse Oximeter ZFPO-A12

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%; 0% to 69%

PR : Measurement range: 30 to 250 bpm
Resolution: 1 bpm
Accuracy: 30bpm to 99bpm ±2bpm; 100bpm to 250bpm ±2%

compare
Pulse Oximeters - Fingertip Pulse Oximeter ZFPO-A13
Fingertip Pulse Oximeter ZFPO-A13

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)
Perfusion Index (PI)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%; 0% to 69%

PR : Measurement range: 30 to 250 bpm
Resolution: 1 bpm
Accuracy: 30bpm to 99bpm ±2bpm; 100bpm to 250bpm ±2%

compare
Pulse Oximeters - Pediatric Fingertip Pulse Oximeter ZFPO-B10
Pediatric Fingertip Pulse Oximeter ZFPO-B10

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%; 0% to 69%

PR : Measurement range: 30 to 250 bpm
Resolution: 1bpm
Accuracy: 30bpm to 99bpm ±2bpm; 100bpm to 250bpm ±2%

compare
Pulse Oximeters - Handheld Pulse Oximeter ZHPO-A10

Handheld Pulse Oximeter ZHPO-A10

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)
Perfusion Index (PI)

SpO₂ Measurement Range : 70% to 100%

SpO₂ Accuracy (No Montion) : Adults: ±2 digits; Pediatrics: ±2 digits

compare
Pulse Oximeters - Handheld Pulse Oximeter ZHPO-A11

Handheld Pulse Oximeter ZHPO-A11

Parameters : Peripheral oxygen saturation (SpO₂)
Pulse rate (PR)
Perfusion Index (PI)

SpO₂ : Measurement range: 70% to 100%
Resolution: 1%
Accuracy: 70% to 100%: ±2%, <70% unspecified

PR : Measurement range: 30 to 250bpm
Resolution: 1bpm
Accuracy: ±2bpm or 2%

compare
Pulse Oximeters - Handheld Pulse Oximeter ZHPO-A12

Handheld Pulse Oximeter ZHPO-A12

Display Mode : Dot matrix color TFT LCD Screen
Size:2.8-inch
Resolutuion: 240 × 320

Storage and Review : Stores data up to 3888 groups

Oxygen Saturation (SpO2) : Measurement Range: 0 to 100%
Accuracy: ±2% (70 to 100%), ±3% (0 to 69%)
Resolution: 1%

Frequently Asked Question

What is a normal pulse rate?

A normal resting heart rate for adults ranges from 60 to 100 beats per minute (bpm). However, athletes or physically active individuals may have lower resting rates.

Is the pulse oximeter accurate?

When used correctly, pulse oximeters are generally accurate within ±2%. However, readings can be affected by movement, nail polish, cold fingers, or poor circulation.

Can nail polish or artificial nails affect the reading?

Yes. Dark-colored nail polish or acrylic nails can interfere with the light sensor and affect the accuracy of the reading. It’s best to use the device on a natural, clean fingernail.

Does a pulse oximeter detect COVID-19?

No. A pulse oximeter cannot detect or diagnose COVID-19, but it can help monitor oxygen levels in people who may be experiencing symptoms like shortness of breath.

Expert Help Desk

Captcha Image