Anesthesia Machine ZAM-A13 operates with gas pressures of 280 to 600 kPa and a 1.5L bellow volume, ensuring consistency. It supports inhalation anesthesia for adult, pediatric, and neonatal patients. The machine’s oxygen concentration adjusts between 15% to 100%. The visual and audio alarms cover power, battery, oxygen levels, and airway pressure, ensuring patient safety. Our hospital anesthesia machine is an indispensable tool for anesthesiologists and healthcare providers.

Specifications:

Ventilation Mode IPPV, A/C, PCV, SIMV, SIGH, MAUN
Gas Source O₂, N₂O, AIR
Flowmeter Range O₂: 0.1 to 10 L/min<br> N₂O: 0.1 to 10 L/min<br> AIR: 0.1 to 10 L/min
Rapid Oxygen Supply 25 L/min to 75 L/min
Oxygen Concentration 15% to 100%
Inspiratory-To- Expiratory Ratio 4:1 to 1:8
Tidal Volume (V<sub>T</sub>) 20ml to 1500ml
Minute Volume (M<sub>V</sub>) ≥ 18L/min
Respiratory Rate (F<sub>req</sub>) 1bpm to 100bpm
Positive End-Expiratory Pressure (PEEP) 0cmH₂O to 30cmH₂O
Pressure Control (P<sub>C</sub>) 5cmH₂O to 60cmH₂O
Pressure Trigger (P<sub>Tr</sub>) -20 cmH₂O to 20 cmH₂O
Flow Trigger (F<sub>Tr</sub>) OFF, 0.5 L/min to 30 L/min
Inspiratory Time (T<sub>insp</sub>) 0s to 12s
Inspiratory Pause (T<sub>IP</sub>) 0s to 6s
Apnea Ventilation OFF, 5s to 60s
SIGH 1/100 to 5/100
Gas Pressure 280kPa to 600kPa
Bellow Volume 1.5 L
Graphical Display P-T (pressure – time)<br> F-T (flow – time)<br> P-V loop (Pressure – volume loop)
Alarms AC Power Failure Alarm: Power failure or no connection<br> Internal Battery Low Voltage: < 10.2 ±0.3V<br> No Tidal Volume: ≤5mL within 6s<br> High Oxygen Concentration: 19% to 100%<br> Low Oxygen Concentration: 18% to 99%<br> High Airway Pressure: 20cmH₂O to 100 cmH₂O<br> Low Airway Pressure: 0 cmH₂O to 20 cmH₂O<br> High Minute Volume: Adult (5L/min to 20L/min)<br> Low Minute Volume: Pediatric (1L/min to 15L/min, 0 to 10L/min)<br> Continuous Pressure: (PEEP + 1.5 kPa) over 16s<br> Suffocation Warning: 5s to 60s no spontaneous ventilation<br> Maximum Limited Pressure: ≤ 12.5 kPa
Error Indicators Fan Error: Shown on screen<br> Oxygen Deficit: Shown on screen
Display 12.1"Colorful TFT LCD display screen
Power Consumption 85VA
Power Supply 100V to 240V, 50/60Hz
Packaging Dimensions 1005 × 960 × 1700 mm
Net Weight 116.5 kg
Gross Weight 227 kg

Features

  • Three-level visual and audio alarms

  • Multiple ventilation modes

  • Adjustable oxygen concentration

  • Rapid oxygen supply

  • Real-time graphical display

  • Patient-triggered ventilation sensitivity

  • 2-3 hours backup battery

  • With altitude compensation

Standard Accessories

Accessories

Quantity

Anesthetic breathing system

1pc

Power cord

1pc

Fuse

3pcs

O₂ cell

1pc

Adult anesthesia breathing circuit (reusable)

2pc

Child anesthesia breathing circuit (reusable)

2pc

Breathing tube

1pc

Y connector

2pc

L connector

2pc

Straight connector

1pc

Reservoir bag 1L

1pc

Reservoir bag 3L

1pc

Anesthetic mask adult

1pc

Anesthetic mask infant

1pc

High pressure O₂ hose

1pc

High pressure air hose

1pc

High pressure N₂O hose

1pc

Auxiliary Common Gas Outlet (ACGO)

1pc

Top light

1pc

Auxiliary AC Power Socket

4pc

Drawers

3pc

Vaporizer

2pc

Optional Accessories

  • Spare Cylinder yoke, 1 O₂, includes gauges

  • Spare Cylinder yoke, 1 N₂O, includes gauges

  • Anesthetic gas scavenging system 

  • Disposable adult breathing circuit

  • Disposable pediatric breathing circuit 

  • Patient monitor 

Applications

Our Anesthesia Machine ZAM-A13 is used in ICUs, operating rooms, and anesthesiology departments for delivering inhalation anesthesia and advanced respiratory management for adults, children, and infants.