Patient Monitor ZPM-A40 features a fetal heart rate range of 60–210 bpm. It also features a non-invasive blood pressure (NIBP) measurement from 50 to 240 mmHg. The built-in data storage and playback function allow easy monitoring and review. Our product delivers clear, real-time data with modern recognition technology for precise measurements. Essential for continuous monitoring of maternal and fetal vital signs during pregnancy, labor, and delivery.
High-sensitivity Doppler transducer
Comprehensive maternal & fetal monitoring
Advanced DSP signal processing
Intuitive LCD & data storage
Flexible power options
User-friendly design
Accessory | Quantity |
Fold Paper | 1 |
TOCO probe | 1 |
FHR probe | 1 |
Marker probe | 1 |
FHR TOCO Marker 3 in 1 probe | 1 |
Bandage | 1 |
Our Patient Monitor ZPM-A40 provides real-time tracking of fetal heart rate (FHR) and uterine contractions (TOCO) for safe and informed delivery management. It is also used in ambulances and emergency departments for quick maternal and fetal assessments in urgent cases.
Transducer | Multi-crystals, pulsed Doppler, high sensitivity |
---|---|
Strength | <5mW/cm² |
Working Frequency | 1.0 MHz |
Signal Processing | Special DSP system and modern recognition |
Measurement Range | 60 bpm to 210 bpm |
Alarm Range | High Limit: 160, 170, 180, 190 bpm Low Limit: 90, 100, 110, 120 bpm |
Maximum Audio Output Power | 1.5 Watt |
Measurement Range | 0 units to 100 units |
Measurement Scope | 70% to 99% |
Measurement Accuracy | ±3% |
Measurement Scope | 30 bpm to 240 bpm |
Measurement Accuracy | ±2 bpm |
NIBP-SYS | 6.7 KPa to 32.0 KPa |
NIBP-DIA | 3.4 KPa to 26.6 KPa |
NIBP-MEAN | 2.0 KPa to 24.0 KPa |
NIBP Accuracy | ±1.1 KPa or ±5% (whichever is greater) |
Maximum Mean Error | ±5 mmHg |
Maximum Standard Deviation | 8 mmHg |
Pulse Rate Accuracy | ±2 bpm or ±5% (whichever is greater) |
Measurement Mode | Manual |
Display | LCD screen displaying FHR, TOCO, FM, maternal parameters, time, date, volume, etc. Data storage and playback capabilities |
Temperature | +5℃ to +40℃ |
Humidity | <85% |
Atmospheric Pressure | 86 KPa to 106 KPa |
Temperature | -10℃ to +55℃ |
Humidity | <93% |
Atmospheric Pressure | 86 KPa to 106 KPa |
Transducer Acoustic Output | Complies with IEC 1157, 1992 standards |
Peak Negative Acoustic Pressure | ≤1 MPa |
Output Beam Intensity | ≤20 mW/cm² |
Spatial-Peak Temporal-Average Intensity | ≤100 mW/cm² |
Gel | Viscous aqueous, non-sensitizing, hypo-allergenic, and non-irritating Indefinite shelf life, bacteriostatic |
Power Consumption | <20W |
Power Supply | AC 100V to 240V, 50/60Hz or 16.8V Li-ION battery |
Dimensions | 355mm × 340mm × 106mm |
Net Weight | Three-parameter type: 4 Kg Nine-parameter type: 4.3 Kg (excluding accessories) |