Electrolyte Analyzers

Zimed Electrolyte analyzers perform multiple tests hourly, ensuring precise ion measurement for diagnosis and effective health monitoring. Multi-channel capabilities allow simultaneous measurement of multiple samples, increasing flexibility. Equipped with intuitive touchscreen interfaces and high throughput, enhance ease of operation and accelerate testing. We offer built-in calibration and quality control ensure accurate and reliable results. Integrated with electronic medical records for clinical workflows. Our electrolyte analyzers are compact and user-friendly, designed to maximize space efficiency.

compare product
  • Specification

    Analysis method Ion selective electrodes ( ISE )
    Output 60 tests / hr
    Sample volume 100 µl
    Parameters K : 0.50 to 10.00 mmol/L
    Na : 30.00 to 200 mmol/L
    Cl-: 30.00 to 200 mmol/L
    Ca2⁺ : 1.10 to 5.00 mmol/L
    pH : 6.00 to 9.00
    Display 128 mm × 64 mm LCD
    Temperature 18 °C to 35 °C ; ≤ 85 %
    Power supply 220 V / 110 V ( AC ); 50 Hz / 60 Hz
    Dimensions 260 × 305 × 140 mm
    Weight 8 kg
  • Features

    • High performance ion selective electrodes
      Automatic sample loading
      Output: 60 tests / hr
      Back illuminated LCD display
      Stores more than 2000 sample results and QC data
      Internalized thermal sensitive printer
compare product
  • Specification

    Analysis method Ion Selective Electrode ( ISE )
    Electrode K, Na, Cl-, Ca2⁺, pH
    Measurement range K : 0.3 to 20.00
    Na : 20.0 to 200.0
    Cl- : 20.0 to 200.0
    Ca2⁺ : 0.1 to 6.0
    pH : 3.00 to 11.00
    Output 60 samples / hr
    Sample volume 100 µl to 200 µl
    Sample type Serum, Urine, CSF
    Operation mode Fully automatic
    Display 5 “ TFT
    Screen 240 mm × 128 mm LCD
    Power ≤80 VA
    Working temperature 15 °C to 30°C
    Relative humidity 20 % to 80 %
    Atmospheric pressure 86.0 kPa to 106.0 kPa
    Weight 6.7 kg
    Printing option Automatic / Manual
  • Features

    • Output : 60 samples / hr
      Ion Selective Electrodes
      Automatic sample load, probe wash and calibration
      Diagnosis of Serum, Urine and CSF
      Thermal sensitive printer
compare product
  • Specification

    Analysis method Ion selective electrodes ( ISE )
    Electrodes K+, Na+, Cl-, Ca2+, pH
    Sample size 100 µl
    Measuring time 25 sec
    Measuring scope K+ : 0.50 to 15.00 mmol/L
    Na+ : 30 to 200 mmol/L
    Cl- : 30 to 200 mmol/L
    Ca2+ : 0.10 to 5.0 mmol/L
    pH : 4.0 to 9.0 mmol/L
    Repeatability error CV % K+ : ≤ 1.0 %
    Na+ : ≤ 1.0 %
    Cl- : ≤ 1.0 %
    Ca2+ : ≤ 1.0 %
    pH : ≤ 1.0 %
    Measuring temperature 10 °C to 32 °C
    Power supply 220 V ± 22 V ( AC );
    50 Hz
    Data storage 10000 reports
    Printing paper 58 mm
    Dimensions 380 × 290 × 310 mm
    Weight 6 kg
  • Features

    • Ion Selective Electrode ( ISE )
      Time for sampling, measuring, washing and printing: 40 second
      Automatic analysis and calibration
      Serum, Whole blood, Plasma, Diluted urine samples
      Sample size : 100 µl
      Thermal sensitive printer