Zimed Syringe Pump are designed for the accurate delivery of fluids in controlled volumes and rates. They are equipped with programmable microprocessor control systems that allow for precise adjustments in flow rates. Their stepper motor mechanism ensures consistent and repeatable syringe movement, accommodating a variety of syringe sizes. Incorporated with user-friendly interface for real-time monitoring of flow rate, total volume dispensed, and operational status. Our Surgical Pump are widely used in medical applications, research laboratories, and industrial processes, where precise liquid handling is crucial.
Syringe Type : 5ml, 10ml, 20ml, 30ml, 50ml, 60ml (of any standard)
Accuracy : ±5% with correct calibration
Flow Rate Control : 50ml(60ml): 0.1 to 2000.0ml/h (0.1ml/h or 1ml/h step)
30ml: 0.1 to 1200.0ml/h (0.1ml/h or 1ml/h step)
20ml: 0.1 to 800.0ml/h (0.1ml/h or 1ml/h step)
10ml: 0.1 to 400.0ml/h (0.1ml/h or 1ml/h step)
5ml: 0.1 to 200ml/h (0.1ml/h or 1ml/h step)
Duration Control : Solution Volume: 0.1 to 9999.9ml (0.1ml step)
Time: 00:01 to 99:59min (1min step)
Syringe Types : 5ml, 10ml, 20ml, 30ml, 50ml, 60ml (of any standard)
Accuracy : ±5% with correct calibration
Flow Rate Control : 50ml(60ml): 0.1 to 2000.0ml/h (0.1ml/h or 1ml/h step)
30ml: 0.1 to 1200.0ml/h (0.1ml/h or 1ml/h step)
20ml: 0.1 to 800.0ml/h (0.1ml/h or 1ml/h step)
10ml: 0.1 to 400.0ml/h (0.1ml/h or 1ml/h step)
5ml: 0.1 to 200ml/h (0.1ml/h or 1ml/h step)
Duration Control : Solution Volume: 0.1 to 9999.9ml (0.1ml step)
Time: 00:01 to 99:59min (1min step)
Syringe Types : 5ml, 10ml, 20ml, 30ml, 50ml, 60ml (of any standard)
Accuracy : ±5% with correct calibration
Flow Rate Control : 0.1ml/h to 2000.0ml/h (0.1ml/h or 1ml/h step)
Duration Control : Solution Volume: 0.1 to 9999.9ml (0.1ml step)
Time: 00:01 to 99:59min (1min step)
Syring Types : 2ml, 5ml, 10ml, 20ml, 30ml, 50ml/60ml
Open system with automatic recognition of syringe brand and size
Accuracy : ±2% with correct calibration
Flow Rate Control : 0.01ml/h to 1500.0ml/h (0.01ml/h)
Infusion Mode : ml/h (includes Rate, Time, Body weight, TIVA, Loading-dose, Ramp up/down, Sequence, Drug Library mode)
Syring Types : 5ml, 10ml, 20ml, 30ml, 50ml/60ml
Various brands of sterile syringe
Accuracy : ±2% with correct calibration
Flow Rate Range : 5ml: 0.1 to 150ml/h
10ml: 0.1 to 300.0ml/h
20ml: 0.1 to 600.0ml/h
30ml: 0.1 to 900.0ml/h
50ml(60ml): 0.1 to 1500.0ml/h
Flow Rate Step : 0.1 to 100ml/h, increment 0.1ml/h
101 to 1500ml/h, increment 1ml/h
Syringe Type : 5ml, 10ml, 20ml, 30ml, 50ml, 60ml (of any standard)
Accuracy : ±5% with correct calibration
Flow Rate Control : 50ml(60ml): 0.1 to 2000.0ml/h (0.1ml/h or 1ml/h step)
30ml: 0.1 to 1200.0ml/h (0.1ml/h or 1ml/h step)
20ml: 0.1 to 800.0ml/h (0.1ml/h or 1ml/h step)
10ml: 0.1 to 400.0ml/h (0.1ml/h or 1ml/h step)
5ml: 0.1 to 200ml/h (0.1ml/h or 1ml/h step)
Programmable 0.01ml/h to 9999.9ml/h
Duration Control : Solution Volume: 0.1 to 9999.9ml (0.1ml step)
Time: 00:01 to 99:59min (1min step)