Talk to us?
Anesthesia Machine ZAM-A13 operates with gas pressures of 280 to 600 kPa and a 1.5L bellow volume, ensuring consistency. It supports inhalation anesthesia for adult, pediatric, and neonatal patients. The machine’s oxygen concentration adjusts between 15% to 100%. The visual and audio alarms cover power, battery, oxygen levels, and airway pressure, ensuring patient safety. Our hospital anesthesia machine is an indispensable tool for anesthesiologists and healthcare providers.
| Ventilation Mode | IPPV, A/C, PCV, SIMV, SIGH, MAUN |
| Gas Source | O₂, N₂O, AIR |
| Flowmeter Range |
O₂: 0.1 to 10 L/min N₂O: 0.1 to 10 L/min AIR: 0.1 to 10 L/min |
| Rapid Oxygen Supply | 25 L/min to 75 L/min |
| Oxygen Concentration | 15% to 100% |
| Inspiratory-To- Expiratory Ratio | 4:1 to 1:8 |
| Tidal Volume (VT) | 20ml to 1500ml |
| Minute Volume (MV) | ≥ 18L/min |
| Respiratory Rate (Freq) | 1bpm to 100bpm |
| Positive End-Expiratory Pressure (PEEP) | 0cmH₂O to 30cmH₂O |
| Pressure Control (PC) | 5cmH₂O to 60cmH₂O |
| Pressure Trigger (PTr) | -20 cmH₂O to 20 cmH₂O |
| Flow Trigger (FTr) | OFF, 0.5 L/min to 30 L/min |
| Inspiratory Time (Tinsp) | 0s to 12s |
| Inspiratory Pause (TIP) | 0s to 6s |
| Apnea Ventilation | OFF, 5s to 60s |
| SIGH | 1/100 to 5/100 |
| Gas Pressure | 280kPa to 600kPa |
| Bellow Volume | 1.5 L |
| Graphical Display |
P-T (pressure – time) F-T (flow – time) P-V loop (Pressure – volume loop) |
| Alarms |
AC Power Failure Alarm: Power failure or no connection Internal Battery Low Voltage: < 10.2 ±0.3V No Tidal Volume: ≤5mL within 6s High Oxygen Concentration: 19% to 100% Low Oxygen Concentration: 18% to 99% High Airway Pressure: 20cmH₂O to 100 cmH₂O Low Airway Pressure: 0 cmH₂O to 20 cmH₂O High Minute Volume: Adult (5L/min to 20L/min) Low Minute Volume: Pediatric (1L/min to 15L/min, 0 to 10L/min) Continuous Pressure: (PEEP + 1.5 kPa) over 16s Suffocation Warning: 5s to 60s no spontaneous ventilation Maximum Limited Pressure: ≤ 12.5 kPa |
| Error Indicators |
Fan Error: Shown on screen Oxygen Deficit: Shown on screen |
| Display | 12.1"Colorful TFT LCD display screen |
| Power Consumption | 85VA |
| Power Supply | 100V to 240V, 50/60Hz |
| Packaging Dimensions | 1005 × 960 × 1700 mm |
| Net Weight | 116.5 kg |
| Gross Weight | 227 kg |
Three-level visual and audio alarms
Multiple ventilation modes
Adjustable oxygen concentration
Rapid oxygen supply
Real-time graphical display
Patient-triggered ventilation sensitivity
2-3 hours backup battery
With altitude compensation
Accessories | Quantity |
Anesthetic breathing system | 1pc |
Power cord | 1pc |
Fuse | 3pcs |
O₂ cell | 1pc |
Adult anesthesia breathing circuit (reusable) | 2pc |
Child anesthesia breathing circuit (reusable) | 2pc |
Breathing tube | 1pc |
Y connector | 2pc |
L connector | 2pc |
Straight connector | 1pc |
Reservoir bag 1L | 1pc |
Reservoir bag 3L | 1pc |
Anesthetic mask adult | 1pc |
Anesthetic mask infant | 1pc |
High pressure O₂ hose | 1pc |
High pressure air hose | 1pc |
High pressure N₂O hose | 1pc |
Auxiliary Common Gas Outlet (ACGO) | 1pc |
Top light | 1pc |
Auxiliary AC Power Socket | 4pc |
Drawers | 3pc |
Vaporizer | 2pc |
Spare Cylinder yoke, 1 O₂, includes gauges
Spare Cylinder yoke, 1 N₂O, includes gauges
Anesthetic gas scavenging system
Disposable adult breathing circuit
Disposable pediatric breathing circuit
Patient monitor
Our Anesthesia Machine ZAM-A13 is used in ICUs, operating rooms, and anesthesiology departments for delivering inhalation anesthesia and advanced respiratory management for adults, children, and infants.