Talk to us?
Talk to us?
Anesthesia Machine ZAM-A16 with a flowmeter range of 0.1 to 10 L/min for each gas, offers flexibility across various clinical scenarios. It allows for customizable inspiratory-to-expiratory ratios from 4:1 to 1:8. The vaporizer integrates temperature, pressure, and flow compensation, along with a self-lock mechanism. Its separate electric and gas circuits enhance durability. Our machine offers multiple customizable triggers, including pressure and flow, for optimal ventilation support.
Ventilation Mode | IPPV, A/C, PCV, SIMV, SIGH, MAUN |
Gas Source | O₂, N₂O/O₂, AIR |
Flowmeter Range | O₂: 0.1 to 10 L/min N₂O: 0.1 to 10 L/min AIR: 0.1 to 10 L/min |
Rapid Oxygen Supply | 25 L/min to 75 L/min |
Oxygen Concentration | 15% to 100% |
Inspiratory-To- Expiratory Ratio (I:E) | 4:1 to 1:8 |
Tidal Volume (VT) | 0,20ml to 1500ml |
Minute Volume (MV) | 0 L/min to 100 L/min |
Respiratory Rate (Freq) | 1/min to 100/min |
Positive End-Expiratory Pressure (PEEP) | 0cmH₂O to 30cmH₂O |
Pressure Control (PC) | 5cmH₂O to 60cmH₂O |
Pressure Trigger (PTr) | -20 cmH₂O to 20 cmH₂O |
Flow Trigger (FTr) | OFF, 1 L/min to 30 L/min |
Inspiratory Time (Tinsp) | 0s to 12s |
Inspiratory Pause (TIP) | 0s to 6s |
Apnea Ventilation | OFF, 5s to 60s |
SIGH | 0 (off) 1/100 to 5/100 |
Gas Pressure | 280kPa to 600kPa |
Bellow Volume | 1.5 L |
Graphical Display | P-T (pressure – time) F-T (flow – time) P-V loop (pressure – volume loop) |
Alarms | AC Power Failure Alarm: Power failure or no connection Internal Battery Low Voltage: < 11.3 ±0.3V No Tidal Volume: ≤5mL within 6s High Oxygen Concentration: 19% to 100% Low Oxygen Concentration: 18% to 99% High Airway Pressure: 20cmH₂O to 100 cmH₂O Low Airway Pressure: 0 cmH₂O to 20 cmH₂O High Minute Volume: Adult (5L/min to 20L/min) Low Minute Volume: Pediatric (1L/min to 15L/min, 0 to 10L/min) Continuous Pressure: (PEEP + 1.5 kPa) over 16s Suffocation Warning: 5s to 60s no spontaneous ventilation Maximum Limited Pressure: ≤ 12.5 kPa |
Error Indicators | Fan Error: Shown on screen Oxygen Deficit: Shown on screen |
Display | 10.4"Colorful TFT LCD display screen |
Power Consumption | 85VA |
Power Supply | 100V to 240V, 50/60Hz |
Packaging Dimensions | 740 × 795 × 1540 mm |
Net Weight | 52.5 kg |
Gross Weight | 119 kg |
For adult, pediatric, and neonatal patients
Multiple ventilation modes
Rapid oxygen supply
Adjustable tidal volume and respiratory rates
Real-time graphical displays
Vaporizer with compensation and safety lock
13 alarms with visual and sound alerts
Built-in battery with 2–3 hours backup
Multilingual interface with 8 languages
Accessories | Quantity |
Anesthetic breathing system | 1pc |
CO₂ sensor | 1pc |
Anesthetic vaporizer | 2pcs |
Power cord (4m) | 1pc |
Fuse (250V) | 11pcs |
O₂ cell | 1pc |
Adult anesthesia breathing circuit (reusable) | 2pc |
Child anesthesia breathing circuit (reusable) | 2pc |
Breathing tube | 1pc |
Y connector (Adult) | 1pc |
Y connector (Children) | 1pc |
L connector | 2pc |
Straight connector | 1pc |
Reservoir bag 1L | 1pc |
Reservoir bag 3L | 1pc |
Anesthetic mask adult | 1pc |
Anesthetic mask infant | 1pc |
High pressure O₂ hose | 1pc |
High pressure air hose | 1pc |
High pressure N₂O hose | 1pc |
Auxiliary Common Gas Outlet (ACGO) | 1pc |
Drawers | 2pc |
Vaporizer | 2pc |
Spare Cylinder yoke, 1 O₂, includes gauges
Spare Cylinder yoke, 1 N₂O, includes gauges
Anesthetic gas scavenging system
Disposable adult breathing circuit
Disposable pediatric breathing circuit
Patient monitor
Our Anesthesia Machine ZAM-A16 is used in intensive care units, operating rooms, and anesthesiology departments for adult, pediatric, and neonatal inhalation anesthesia and respiratory management.
Frequently Asked Question
The machine is equipped with multiple alarms to ensure patient safety and system functionality, including: AC Power Failure Alarm: Indicates power failure or no connection. Internal Battery Low Voltage Alarm: Triggers when voltage falls below 11.3V ±0.3V.
No Tidal Volume Alarm: Triggers if tidal volume is ≤5mL within 6 seconds. High and Low Oxygen Concentration Alarms: High: 19% to 100% Low: 18% to 99% High and Low Airway Pressure Alarms: High: 20 cmH₂O to 100 cmH₂O Low: 0 cmH₂O to 20 cmH₂O
Yes, it includes alarms for high and low minute volumes based on patient type: High Minute Volume (Adult): 5L/min to 20L/min Low Minute Volume (Pediatric): 1L/min to 15L/min (0 to 10L/min)
This alarm triggers if PEEP + 1.5 kPa is maintained for over 16 seconds, indicating excessive airway pressure.
The suffocation warning activates if no spontaneous ventilation is detected for 5 to 60 seconds, prompting immediate intervention.
The Zimed Anesthesia System is a medical device used to deliver anesthetic gases and oxygen to patients during surgery or medical procedures. It ensures the patient remains unconscious, pain-free, and stable throughout the operation.
Our machine delivers a controlled mixture of gases, which the patient inhales through a mask or endotracheal tube. The ventilator supports breathing, and the vaporizer ensures precise delivery of anesthetic agents. Sensors monitor vital signs and gas concentrations for safety.
Yes, our anesthesia machines can function as ICU ventilators, providing long-term mechanical ventilation support for critically ill patients when needed.
The scavenging system collects excess anesthetic gases and vents them safely outside the operating room. Proper ventilation and personal protective measures further reduce exposure risks.